Dongli reference library · Confirm model fitment and availability with our team

Pump reference

SC-170H pump reference

APLEX / SC-170HDocumented source recordPage / reference 10, 14, 29, 31, 32

Check source

Supply identity and fitment need confirmation; this reference is not a price or stock commitment.

Source brand
APLEX
Model
SC-170H
Source reference
SC-170H

APLEX / SC-170H

Source-page image withheldSC-170HCheck the source record
A third-party catalogue page was used for source identification. Its image is withheld from this public index while redistribution rights are checked.

What the source says

The SC-170H-specific engineering page in the supplied Pentair / MYERS APLEX manual describes a triplex pump with a 4140 forged-steel liquid end, removable stuffing boxes and pressure lubrication. Its valve and packing options must be checked against the installed assembly.

Prepare an inquiry

Identification reference. Supply identity and fitment require confirmation. No price or stock commitment.

About this reference

SC-170H pump reference — reference SC-170H. This entry is organized under APLEX / SC-170H using the supplied documentation. The source reference identifies a catalog entry; it does not establish interchangeability or current availability. This pump entry supports equipment identification and configuration enquiries. Selection requires a documented operating point and a confirmed supply scope, including whether the drive and accessories are included. Page 10 lists chromium-oxide-coated 316 stainless-steel plungers, removable carbon-steel stuffing boxes, and spring-loaded Style 120X or Style 140 packing. The valve entries distinguish hardened-and-lapped disc, optional dual-stem-guided and optional abrasion-resistant arrangements. The presence of several valve options is not a claim that one replacement kit fits them all. Page 31 identifies this model in both the right-/left-hand crankshaft assembly group and a separate right-hand Auburn Gear #8 group; page 32 lists a left-hand gear-drive group. Confirm drive side, shaft or spline arrangement and assembly reference before ordering. The engineering tables and the general installation text use different continuous/intermittent-duty wording, so no continuous-duty promise or pressure-flow operating point is adopted here. Supply the nameplate, serial number, existing component marks and duty requirements for configuration checking. Archive listings do not prove stock, current OEM status or cross-model interchangeability.

Selection & verification

Provide the nameplate, required flow and pressure, fluid, drive speed and installation envelope for selection.

Have the equipment reference ready?

Search this model in the catalog ↗

Documented details

Stroke (model-specific archive table)4-1/4 in
Power-end lubrication (archive table)Pressure lubrication / 压力润滑

Before you inquire

Confirm the pump nameplate, exact model, existing part number and configuration. Reference numbers are not company stock codes.

Source documentation

Pentair / MYERS APLEX AP-03-104 installation and service manual, 01/03/17; SC-170H engineering and assembly references
Page / reference: 10, 14, 29, 31, 32

A third-party source-page image (PDF page 1) is withheld from this public index while redistribution rights are checked. The cited model and page reference remain available for technical review. Contact Dongli ↗

Browse separately reviewed same-model manuals →

View source record and citing products →

Technical references

Check the original parts pages

Browse this brand’s manuals ↗

Brand and model labels match. These references do not establish this product's source, interchangeability or fitment. Confirm configuration and revision.

  • SC-170L.pdf

    General reference; HDD applicability not verified.

    Original reference; confirm configuration, revision and individual part fitment.

    Ask about cited PDF page 33 ↗
  • ap-03-104-ma-sc-series-triplex-pumps-iom.pdf

    General reference; HDD applicability not verified.

    40-page AP-03-104, 01/03/17; verify fluid-end material and SC-170DD configuration.

    Ask about cited PDF page 29 ↗

Questions before ordering

How do I identify reference SC-170H?

Compare SC-170H and the listed name “SC-170H pump reference” with the original part marking and the SC-170H documentation. Include the full number and suffix in your inquiry.

What should I confirm for this sc-170h pump reference?

Provide the nameplate, required flow and pressure, fluid, drive speed and installation envelope for selection.

Can SC-170H be selected by model name alone?

No. The APLEX / SC-170H grouping is a source-catalog context. Confirm the full reference, equipment revision and drawing details before treating this item as a match. Material, pressure rating, stock and interchangeability require separate confirmation.

APLEX / SC-170H

Ready to discuss this reference?

Save this source reference, then include the nameplate, configuration and required quantity for Dongli to verify.

Review inquiry draft →

Compare references

Compare identification details. Similar specifications do not confirm interchangeability.